arrow-backarrow-rightattachmentdownloadenvelopehomeinfo-requestinternetlinklogo-controls-grouplogo-controlsmagnifying-glassmainslider-arrow-leftmainslider-arrow-rightmarkerphoneshare-emailshare-facebookshare-google-plusshare-linkedinshare-pinterestshare-twitterslider-arrow-leftslider-arrow-rightsocial-facebooksocial-linkedinsocial-twittersocial-youtubeswipevideo

Automatic Vicat apparatus

Automatic setting time tester for cement, mortar and gypsum

EN 196-3 | EN 480-2 | ASTM C191 | AASHTO T131

Main Features

  • New functional and ergonomic design based on the innovative CVi-TECH philosophy invented by CONTROLS througt the recent years
  • Advanced electronics technologies providing superior performances and total flexibility combined with simplicity in use
  • Easy-to-use double interface: local mode, with large size 4,3" touch screen color display, and remote mode, with PC
  • Supplied complete with PC software for data processing VICASOFT-BASIC
  • With PC software VICASOFT-PREMIUM (optional) up to 32 indipendent units can be connected to a single PC via LAN port and hub. All units are remotely controlled. Adopting the multi-test network concept laboratory productivity is maximized
  • Integrated graphic printer is available as optional accessory showing both results in numerical format and setting time plot
  • Easy setting and storage of user-defined test profiles allowing quick test start
  • Large accessibility to the test space
  • Practical in-water testing accessory (optional)
  • Automatic determination of initial and final setting time
  • tecnical specifications
    • Scroll the table
      Technical specifications
      • Conforming to EN 196-3, 13279-2, 480-2, ASTM  C191, C187
      • Large size 4,3" touch screen color display
      • LAN port for direct connection to PC of a single unit or connection to a LAN hub for creating a network with up to 32 independent units all controlled by a single PC. 1 LAN cable is included
      • USB port for data storage on pen-drive (included)
      • Test procedures can be customized and stored to match user-defined requirements
      • Can incorporate an integrated graphic printer showing test result and setting time plot
      • Large test space with easy accessibility
      • Automatic calculation of initial and final setting time at programmable penetration depth limits
      • Wide range of accessories including EN and ASTM/AASHTO parts, in-water testing kit, needle cleaning device, integrated printer, probes for testing consistency and gypsum
      • Minimum penetrations rate: 10 seconds
      • Penetration measurement by encoder    
      • Power: 50 W
      • Dimensions: 200x400x410mm (L x W x H)
      • Weight approx.: 10 kg

      Firmware specifications
      • Easy programming of customized test profiles, recallable for future tests, including:
        • adjustable test start delay
        • penetration points positions 
        • manual or automatic penetration rate
        • free or driven dropping mode
        • holding intervals inside the sample
        • automatic end- test detection
        • automatic measurement of initial and final setting time     
      • Test data: test number, operator, client, date, hour, cement type, water percentage, delay 
      • Easy calibration menu         
      • Clock calendar
      • Multi-language
  • ordering info
    • 63-L2700/E
      VICAMATIC-2, automatic electronic apparatus for setting time test on cement/mortar/gypsum. Complete with EN 196-3 accessories: initial setting time needle 1.13 mm dia., mould and PC software VICASOFT-BASIC.
      110-240V, 50-60Hz, 1ph.

      63-L2700/F
      VICAMATIC-2, automatic electronic apparatus for  setting time test on cement/mortar/gypsum. Complete with ASTM C191 accessories: initial setting time needle 1.00 mm dia., mould and PC software VICASOFT-BASIC.
      110-240V, 50-60Hz, 1ph.

      63-L2700
      VICAMATIC-2, automatic electronic apparatus for  setting time test on cement/mortar/gypsum complete with PC software VICASOFT-BASIC. Supplied without accessories (mould, needle and mould centering ring).
      110-240V, 50-60Hz, 1ph.
  • accessories
    • Accessories

      63-L2700/E10
      Accessory for needle cleaning and in-water testing

      63-L2700/E11
      LAN hub for PC connection of up to 7 VICAMATIC-2 units or up to 6 units in case of multi-hub network. LAN cable from hub to PC is included. Each VICAMATIC-2 unit is supplied complete with LAN cable

      63-L2700/PR
      Upgrading of a VICAMATIC-2 unit for incorporating a graphic printer into the head. Test settings and results are plotted both as numerical and graphical format including penetration depth/time diagram. The upgrading shall be factory installed

      63-L2700/E14
      Needle for final setting test to EN

      63-L2700/E15
      Cylindrical probe for consistency test.

      63-L2700/F15
      Cylindrical probe and addition weight for consistency test to ASTM C807. 

      63-L2700/E16
      Additional weight 700 g

      63-L2700/E18
      Conical penetration probe 8 mm dia x 50 mm complete with 100g calibrated weight for gypsum testing to EN 13279

      63-L2700/F21     
      2 mm dia. needle to ASTM C807

      63-L2700/F23     
      Brass cylindrical mould to ASTM C807

      63-L0027/E9
      Water thermostatic unit for VICAMATIC -2. Up to 2 units may be connected. 230 V, 50-60 Hz, 1 ph
      63-L0027/E9Z
      Same as above, but 110 V, 60 Hz, 1 ph

      82-SW/VS
      VICASOFT-PREMIUM software for PC connection of up to 32 VICAMATIC-2 units including remote control of each unit, data acquisition - processing - filing, printout of  test reports.
      Communication via LAN port (each VICAMATIC-2 unit is supplied complete with LAN cable). The connection of one VICAMATIC-2 unit is direct via the PC LAN-port, for more VICAMATIC-2 units (up to 32) one or more LAN hubs are required with total number of ports equal (or bigger) to the number of VICAMATIC-2 units included in the network. LAN hubs are not included


      Spare parts
      63-L2700/1
      Cenitering ring for EN mould

      63-L2700/2
      Centering ring for ASTM mould

      63-L2700/E20
      1,13 mm dia. needle for initial setting time test to EN

      63-L2700/E21    
      1 mm dia. needle for setting time test to ASTM/AASHTO

      63-L0027/E22    
      Plastic mould to EN

      63-L0027/E23    
      Plastic mould to ASTM/AASHTO

      63-L2700/E24    
      Glass base plate

      63-L2700/E25    
      Spare base plate for in-water testing kit