arrow-backarrow-rightattachmentdownloadenvelopehomeinfo-requestinternetlinklogo-controls-grouplogo-controlsmagnifying-glassmainslider-arrow-leftmainslider-arrow-rightmarkerphoneshare-emailshare-facebookshare-google-plusshare-linkedinshare-pinterestshare-twitterslider-arrow-leftslider-arrow-rightsocial-facebooksocial-linkedinsocial-twittersocial-youtubeswipevideo

Next generation Asphalt Mixture Performance tester AMPT Pro

Next generation asphalt mixture performance tester AMPT Pro
AMPT Pro control panel
AMPT Pro transducers

Main Features

  • Significantly improved ECU performance and innovation
  • Temperatures: 23 degrees Celsius at temperatures below +15 ° C
  • The new Hydraulic Power Supply (HPS) uses inverter technology coupled with a high performance labyrinth bearing actuator to deliver 19 kN of force
  • Easy-to-use and ergonomic testing system
  • Interchangeable transducers and load cells with "plug and play" signal conditioners allowing for quick and easy transition of test set-ups
  • Clarity in results with the Integrated Mutli Axis Control System (IMACS)
  • All-in-One computer control with the latest All-in-One touchscreen PC technology
  • Fully integrated and compact in design, a perfect solution for both static and mobile testing facilities
  • Optional air compressor that comes integrated
  • tecnical specifications
    • Scroll the table
      • Load Capacity: Static: 19kN, Dynamic 17kN
      • Frequency Range: 0.01 to 70Hz sinusoidal loading
      • Actuator Stroke: 30mm (+/- 15mm stroke)
      • Actuator Type: Labyrinth Bearing
      • Specimen Size (dia xh): 100 x 150 mm nominally, 50 x 135 mm, 38 or 50 x 110 mm 
      • Temperature Range: -5 ° C to + 70 ° C *
      • Cooling Rate: Typically cools to + 4 ° C in under 30 minutes (at an ambient temperature of + 23 ° C)
      • Temperature Accuracy: +/- 0.2 ° C (at temperature probe placed close to the specimen)
      • Cell Dimensions (dia xh): 270 x 390mm
      • Confining Pressure: 0 to 225 kPa
      • Noise Level: Less than 70db at 2m
      • Computer Control: Integrated all-in-one PC touchscreen (optional)
      • Air Compressor and Dryer: Low noise, integrated, automated operate-on-demand (optional)
      • Easily interchangeable load cells test
      • Supplied complete with high quality pre-filtered oil for longer life
      • Dimensions (hxwxd): 1,359 x 1,350 x 739mm 
      • Weight: 275kg (including oil)
      Transducers
      • Load Cell: Low profile pancake type
      • Built-in LVDT Actuator: 30mm Stroke
      • Pressure: 0 to 225 kPa
      • On-Specimen Displacement: 3 clips on +/- 0.5mm LVDTs Compatible with up to 4 (Various optional loose-core, strain gauge transducers available)
      • Temperature Probe Range: from -25 up to +80° C
      • Plug-and-Play: Up to 4 interchangeable on-specimen displacement transducers, plus easily interchangeable load cells

      Services
      • Power (without air compressor): 220V–240V, 50Hz, single phase, 17A 208V, 60Hz, single phase, 20A
      • Power (with air compressor): 220V–240V, 50Hz, single phase, 22A 208V, 60Hz, single phase, 25A
      • Air: Clean dry air at 450-800kPa; 2 L/sec (Optional integrated air compressor available)
      • Hydraulic Oil: Pre-filled with high specification pre-filtered, ISO 46 Premium Mineral Oil
      Control & Data Acquisition—IMACS
      • Configuration: Fully integrated
      • Real Time Digital Computer Control: 32-bit Processing
      •  Acquisition Speeds: 5kHz (simultaneous on all channels)
      • Data Over-Sampling: At least 4x
      • Data Resolution: 20-bit auto-ranging data acquisition
      • Communication: USB 2.0 at 12Mb/s, Ethernet at 10/100Mb/s
      • Firmware Update: Flash based
      •  Analogue Inputs: Auto-calibrate on power up
      •  Analogue Outputs: 8 BNC connectors for raw data logging
      • Control: 2 axis control (actuator and confining pressure)
      •  Acquisition: Up to 8 Channel data acquisition (actuator displacement, axial load, 3 to 4 on-specimen displacement transducers, confining pressure and temperature)
  • ordering info
    • 79-PV71A12
      AMPT Pro - Asphalt Mixture Performance Tester, complete with 19kN static / 17kN dynamic actuator with labyrinth bearing, automatic cell confinement with integrated temperature control, -5 to + 70 ° C range, 20kN load cell, 30mm actuator LVDT, 225 kPa pressure transducer, -25 ° + 80 ° C temperature transducer, Hydraulic Power Supply and IMACS. Includes Dynamic Modulus E *, Flow Number and Flow Time testing modules.
      208-230V / 50-60Hz / 1Ph. 
  • accessories
    • Transducer and mounting kit for the above Testing Modules
      79-PV71010
      AMPT Pro On-Specimen LVDT Assembly - IPC guided Spring Core Black. Includes ILC Pod and LVDT Target Clamps x2
       
      79-PV71011
      AMPT Pro On-Specimen LVDT Assembly - IPC guided Spring Core Blue. Includes ILC Pod and LVDT Target Clamps x2
       
      79-PV71012
      AMPT Pro On-Specimen LVDT Assembly - IPC guided Spring Core Green. Includes ILC Pod and LVDT Target Clamps x2
       
      79-PV70524
      AMPT Pro Gauge Pornt Fixing Jig Assembly -NO gauge point Heads. Includes membrane stretcher
       
      79-PV71031
      AMPT Pro Gauge Point Fixing Jig - Setting Arm Hex Kit - set of 3
       
      79-PV70507
      AMPT consumable kit
       
      Notes:
      The above items are needed to complete the Test Modules supplied with the machine (Standard outfit). Loose -Core and Epsilon transducers are available as alternatives on request.


      Machine accessories (Optional)
      79-PV71000
      AMPT Pro -All-in-One Touch Screen PC Assembly
       
      79-PV70502
      Proving Ring Assembly TP79 / T342 / TP62 / TP107 SVECD / AMPT. Includes 6 AMPT Proving Ring HEX gauge points and 6 Socket Head Cap Screw M2.5 x 16 SS gauge Screws
       
      79-PV71001
      AMPT Pro - Air Compressor assembly, Max air flow 137 l / min, 8 Bar cap ,. 5 liters tank, with air dryer with molecular sever. With port fpr gauge point fixing jig. 220 V, 50 HZ, 1 ph.
       
      79-PV71002
      AMPT Pro - Air Compressor assembly, Max air flow 137 l / min, 8 Bar cap ,. 5 liters tank, with air dryer with molecular sever. 220 V, 60 HZ, 1 ph.
       
       79-PV70507
      AMPT consumable kit
       
      AMPT Pro Dynamic Modulus E * small diameter specimen kit (38 & 50 mm dia.)
       
      79-PV71210
      AMPT 38 mm Specimen Platen Kit (top 6 bottom platens set)
       
      79-PV71211
      AMPT 50 mm Specimen Platen Kit ( top 6 bottom platens set)
       
      79-PV71212
      AMPT LVDT Gauge Point Fixing Jig 38 mm Specimen Upgrade Kit
       
      79-PV71213
      AMPT LVDT Gauge Point Fixing Jig 50 mm Specimen Upgrade Kit
       
       
      AMPT Pro Uniaxial Fatigue small diameter specimen kit (50 mm dia.)
      79-PV70617
      Uniaxial Fatigue Glue Jig - 50 mm Specimen Retro-fit Kit
       
      79-PV70618
      AMPT 50 mm Specimen Platen
       
      79- PV71213
      AMPT LVDT Gauge Point Fixing Jig 50 mm Specimen Upgrade Kit
       
      79-PV70619
      AMPT SVECD - Top & Bottom Spacer Kit - for testing 50 mm diameter x 110 mm specimens

Related products

New products

Our locations


Follow us on