arrow-backarrow-rightattachmentdownloadenvelopehomeinfo-requestinternetlinklogo-controls-grouplogo-controlsmagnifying-glassmainslider-arrow-leftmainslider-arrow-rightmarkerphoneshare-emailshare-facebookshare-google-plusshare-linkedinshare-pinterestshare-twitterslider-arrow-leftslider-arrow-rightsocial-facebooksocial-linkedinsocial-twittersocial-youtubeswipevideo

Digital instrumentation

ASTM E74

Digimax Plus 82-P0801/E (in the middle) with 3000 kN load cell 82-E0100/300 and 82-P0172/M printer
82-P0801/E
Example of print of calibration test results obtained by simply connecting the 82-P0172/M to the 82-P0801/E tester.
Example of display
Final force calibration certificate obtained with the connection to PC and the 82-P0804/E4 MS EXCEL template.
Final force calibration certificate obtained with the connection to PC and the 82-P0804/E4 MS EXCEL template
82-P0172/M

Main Features

  • High resolution: 256,000 points ( less than 0.05% of full scale)
  • Large graphic display: 240x128 pixel
  • Language selection: English, French, Spanish, German and Italian
  • Large permanent memory: up to 960 readings
  • Two RS 232 serial ports for PC and printer
  • Remote control
  • MS EXCEL Template available for producing calibration certificates conforming to EN/ASTM   standards
  • tecnical specifications
    • Scroll the table
      • Microprocessor based
      • Clock calendar chip
      • Large permanent memory to store data and test results
      • Two RS 232 serial port for PC and printer
      • Analogic channel for strain gauge load cells/transducers, 256,000 points resolution
      • Graphic display 240x128 pixel
      • Dimensions: 250x220x150 mm
      • Weight approx.: 2 kg
  • ordering info
    • 82-P0801/E 
      Digimax Plus, calibration tester, for use with load cells or transducers, 236,000 points resolution. 230 V, 50-60 Hz. 1 ph.

      82-P0801/EZ 
      Digimax Plus, calibration tester, for use with load cells or transducers, 236,000  points resolution. 110 V, 60 Hz. 1 ph.

      Calibration certificate for load measurement shall be ordered separately when the digital redout unit will be purchased along with the load cell/s.
       
      82-E0100/ACC1 
      Official ACCREDIA (EAL) calibration certificate   for the load cell connected to suitable digital tester for force verification. Calibration to EN  ISO 376, 10 points, 4 cycles. (increasing forces only). Suitable for load cells from >1 to 10 kN    
       
      82-E0100/ACC2
      Official ACCREDIA (EAL) calibration certificate   for the load cell connected to suitable digital tester for force verification. Calibration to EN  ISO 376, 10 points, 4 cycles. (increasing forces only). Suitable for load cells from >10 to 600 kN    
       
      82-E0100/ACC3
      Official ACCREDIA (EAL) calibration certificate   for the load cell connected to suitable digital tester for force verification. Calibration to EN  ISO 376, 10 points, 4 cycles. (increasing forces only). Suitable for load cells from >600 to 1000 kN    
       
      82-E0100/ACC4
      Official ACCREDIA (EAL) calibration certificate   for the load cell connected to suitable digital tester for force verification. Calibration to EN  ISO 376, 10 points, 4 cycles. (increasing forces only). Suitable for load cells from >1000 to 5000 kN   

      82-E0100/TRC  
      Traceable calibration certificate  for load cells from 5kN to 5000 kN cap., connected to the relevant Digital tester
       

  • accessories
    • 82-P0172/M       
      24 column serial printer. 110-230 V, 50-60 Hz, 1 ph.

      82-P0172/1  
      Serial cable for printer connection

      82-P0804/E4
      MS EXCEL Template for force calibration verification

      82-P0800/C 
      Hard plastic carrying case for 82-P0801/E tester and serial printer                      